                  Features:

                  Display: 6000 counts

                  DC/AC Current Measurement
                  DC/AC Voltage Measurement
                  Resistance/Continuity/Frequency Measurement
                  Automatic measuring range
                  Full measuring range overload protection
                  True RMS
                  Auto power off
                  Backlight
                  Low Battery indication
                  Date hold
                  V-alert Test(dangerous voltage alarm)
                  Live wire and null wire test

                  Specifications:

                   
                  Max voltage allowed at the measuring end.:600V DC or 600AC(RMS).
                  Work height: max 2000m
                  Display:LCD.
                  Max display value: 5999 digits.
                  Polarity indication:Self-indicating, ‘-’ means Negative polarity. Over-range display:‘0L’ or ‘-0L’.
                  Sampling time:The meter figures show about 0.4 seconds
                  Unit display
                  :
                  Function and battery unit display.
                  Automatic Power off time: 15 minutes
                  Operational power
                  :1.5Vx2 AAA battery.(not included)
                  Battery low voltage indication: LCD display symbol.
                  Temperature coefficient:Less than 0.1 x Accuracy / ℃
                  Operational temperature and humidity : 0~40 ℃/32~104℉ 45%-80%RH
                  Storage temperature and humidity
                  :-10~60 ℃/-4~140℉ 45%-80%RH
                  Boundary dimension
                  :
                  139×83×36mm
                  Weight: ~160g

                  1. Voltage DC
                   

                  Range Resolution Accuracy
                  600V 0.1V ±(0.8%+3counts)

                  Sensitivity: min 0.5V DC voltage Input impedance: 1MΩ
                  Max input voltage
                  :600V DC&AC (RMS)

                  2. Voltage AC
                   

                  Range Resolution Accuracy
                  600V 0.1V ±(1.2%+5counts)

                  Sensitivity: min 0.5V DC voltage Input impedance: 1MΩ
                  Max input voltage
                  :600V DC&AC (RMS)
                  Frequency range: 50Hz~60Hz, true RMS response.
                   
                  3. Resistance
                   

                  Range Resolution Accuracy
                  6000Ω ±(1.2% +3counts)

                  Overload protection:600V DC or AC(RMS)
                   
                  4. Current DC
                   

                  Range Resolution Accuracy
                  200mA 0.1mA ±(1.2%+3 counts)

                  Sensitivity: min 0.5mA DC current.
                  Overload protection
                  :600V/200mA self-recovery fuse. Frequency range: 50Hz~60Hz.
                   
                  5. Current AC
                   

                  Range Resolution Accuracy
                  200mA 0.1mA ±(1.5%+5counts)

                  Sensitivity: min 1mA AC current.
                  Overload protection: 600V/200mA self-recovery fuse. Frequency range: 50Hz~60Hz.

                  6. Frequency

                  Range Resolution Accuracy
                  1000Hz 1Hz ±(1.0%+5counts)

                  Frequency range: 40Hz~1000Hz.
                   
                  7. Measure Continuity
                   

                  Function Accuracy
                   
                  buzzer
                  If the resistance is <30Ω,
                  the continuity beeper
                  sounds.

                  Overload protection:6000V DC or AC(RMS)
                   
                  8. V~Alert
                   

                  Range Explanation
                  Low file Show -EF-, green V~Alert light continue light on, the beep sounds
                  Hgh file Show -EF-, red NCV light continue light on, the buzzer sounds an alarm
                  at a higher frequency

                  Package Includes:

                  1 x 
                  1 x Pair of Probes 
                  1 x English User Manual
                  1 x Package Box

                  Detail Pictures: