Price:
US$214.45
Compatibility
To confirm that this part fits your vehicle, please enter your vehicle's details below.
-
Year:
Select
-
Make:
Select
-
Model:
Select
-
Submodel:
Select
-
Trim:
Select
-
Engine:
Select
- Clear All
Show all compatible vehicles
- Year
- Make
- Model
- Submodel
- Trim
- Engine
Performance of Scope |
|||
B Bandwidth (-3dB) |
50MHz |
||
Sampling Rate |
Max. real time sampling rate 200MSa/s |
||
Channel |
1 |
||
Coupling |
AC, DC |
||
Rise Time |
≤ 7.6ns |
||
Input Impedance |
1MΩ, ≤ 20pF |
||
Max Input Voltage |
1x CAT III 300 VAC 10x, 100x CAT III 600 VAC |
||
Vertical Resolution |
8 bit |
||
Vertical Sensitivity |
10mV/div – 5V/div |
||
Horizontal Resolution |
2ns/div |
||
Horizontal Sensitivity |
2ns – 5s |
||
Record Length |
4K/channel |
||
Memory |
6 memory locations |
||
Trigger Mode |
Auto, Normal, Single |
||
Trigger Type |
Edge trigger |
||
Basic Performance |
|||
Screen |
320×240 pixels (RGB), with LED backlight |
||
Communication |
USB, PC software |
||
Battery |
3.7V lithium polymer battery, 4Ah |
||
Adapter |
Input Voltage: 100Vac – 240Vac
Output: 5Vdc ± 10%, 2000mA
|
||
Operating Environment |
Temperature: 0℃ – 40℃ |
||
Humidity: ≤ 75% |
|||
Storage Environment |
Temperature: -10℃ – 50℃ |
||
Humidity: ≤ 85% |
|||
Operating Altitude |
0 – 2000m |
||
Size |
218mm × 118mm × 50mm ( including holster ) |
||
Weight |
700g(main body only) |
||
Performance of multimeter |
|||
Display |
6000 counts |
||
Input |
Max. Input Voltage: 600 Vrms CAT II, 300 Vrms CAT III |
||
Continuity Test |
Beeps at < 25Ω, in 600Ω range |
||
Diode Test |
If the voltage drop of the diode under test is more than 2V |
||
Capacitance Measurement |
6.000nF – 6mF |
||
Resistance Measurement |
600.0Ω – 60.00MΩ |
||
Voltage Measurement |
6.000V – 600V |
||
Waveform output performance |
|||
Amplitude |
Output amplitude is adjustable. Output amplitude range: 0 – 2.5V Output amplitude accuracy: ± 2% for amplitudes < 2V ± 5% for amplitudes > 2V |
||
Frequency |
There is no frequency setup for dc output. Output frequency range: 26Hz – 50kHz Output frequency accuracy: ± 2% |
Specification of Scope |
|
Vertical System: channel of Scope |
|
Bandwidth (-3dB) |
50MHz |
Accuracy |
10mV/div to 20 mV/div: ± 5% full scale |
50mV/div to 5V/div: ± 3% full scale |
|
Vertical Offset Accuracy (DC) |
±0.2 div ±2mV ±0.5% offset value |
Trigger Sensitivity |
DC to 50 MHz: 0.8 div |
Horizontal System: time base of Scope |
|
Horizontal Sensitivity |
2ns/div – 5s/div, in 1-2-5 step |
Horizontal Accuracy |
< ( 0.01% + 1 pixel ) |
Specification of probe |
|
Rise Time |
X1 < 23.3ns |
X10 < 7.6ns |
|
Bandwidth |
X1 DC – 8MHz |
X10 DC – 50MHz |
|
Input Impedance |
X10 10MΩ (not including the Scope's input resistance 1MΩ) |
Input Capacitance |
X1 46pF ( not including the Scope's input capacitance ) |
X10 about 15pF |
Specification of Multimeter |
|||
Function |
Range |
Frequency, test current, or load voltage |
Condition: at calibration temperature±5℃, for 1 year |
Voltage |
|||
DC Voltage |
6.000V |
|
1.0 + 8 |
60.00V |
|
0.5 + 8 |
|
600.0V |
|
0.5 + 8 |
|
AC Voltage |
6.000V – 600.0V |
40Hz – 400Hz |
1.0 + 10 |
400Hz – 2kHz |
5.0 + 10 |
||
Resistance |
|||
|
600.0Ω |
|
1.0 + 5 |
|
6.000kΩ |
|
1.0 + 5 |
|
60.00kΩ |
|
1.0 + 5 |
|
600.0kΩ |
|
1.0 + 5 |
|
6.000MΩ |
|
1.0 + 5 |
|
60.00MΩ |
|
2.0 + 10 |
Capacitance |
|||
|
6.000nF |
|
3.0 + 8 |
|
60.00nF |
|
3.0 + 8 |
|
600.0nF |
|
3.0 + 8 |
|
6.000μF |
|
3.0 + 8 |
|
60.00μF |
|
3.0 + 8 |
|
600.0μF |
|
3.0 + 8 |
|
6.000mF |
|
3.0 + 8 |
|
|||
Continuity |
Buzzer beeps if the resistance is less then about 25Ω. |
||
Diode |
Buzzer beeps if the forward voltage drop of the diode is < 0.25V. |