Price:
US$13.56 ~ 14.56

Free Shipping

BY62 DC 0-500V 4 Bit Voltage Current Capacity Power Temp Meter OLED Multifunction DC Electric Parameter Tester

Compatibility

To confirm that this part fits your vehicle, please enter your vehicle's details below.

  • Year:

    Select

    • Make:

      Select

      • Model:

        Select

        • Submodel:

          Select

          • Trim:

            Select

            • Engine:

              Select

              • Clear All
              This part is compatible with 0 vehicle(s).
              Show all compatible vehicles
              This part is compatible with 1 vehicle(s) matching
              This part is not compatible with
              Recent searches

                • Year
                • Make
                • Model
                • Submodel
                • Trim
                • Engine

                  Type 1: DC Parameter Meter+100V  20A out shunt
                  Type 2: DC Parameter Meter+100V   50A out shunt
                  Type 3: DC Parameter Meter+100V  100A out shunt

                  Reminder:

                   
                  The photo is used to demonstrate the working principle and appearance of the product. So we chose one of the parameters to take photos, showing that the resolution can not correspond to all specifications. The corresponding product's resolution is based on the number in the webpage introduction.

                  Technical parameters
                   
                  Voltage meter range: 00.00-99.99V  
                  Current meter range: Purchase choice
                  Measurement power: 0.000W-150KW [decimal point and unit automatically adjusted according to actual results]
                  Real time power: 0.000AH-999.9AH [decimal point automatically adjusted according to actual results]
                  Accumulative energy:  0.000AH-99999AH [decimal point automatically adjusted according to actual results]
                  Cumulative watt time: 0.000WH-99999WH [decimal point automatically adjusted according to actual results]
                  Temp measurement: -15.0 degree to 65 degrees [resolution 0.1 degrees]
                  Time shows: 0-99 hours and 59 minutes [Load timing]
                  Automatic memory: 1 This time of electricity, 2 Add electricity many times. 3 Multiple additive energy
                  Internal resistance of the voltmeter: 400KΩ
                  Internal resistance of the ammeter:1A0.1Ω  1A25mΩ  5A10mΩ 10A5mΩ  30A2.5mΩ  50A1.5mΩ  100A0.75mΩ  200A0.375mΩ 
                  Working voltage: DC5-12V  *1
                  Measurement accuracy: 0.2%(+/-2)*2
                  Operating temperatur: -10℃~60℃ 
                  Working current: <15mA
                  Refresh rate: 2 times/second
                  Communication function: provide TTL interface output data.3.3V5V compatible.
                  Display mode: 0.96 OLED 
                  Overall dimensions: 48MM*29MM*21MM(L*W*H)
                  Opening size: 45.5mm*26.5mm
                  Lead wire length: 13CM
                      *1:The instrument can work in dc4-28v, but it will be hot when it is above 15V and reduce the accuracy and life. Please use 5-15V power supply.
                      *2:Error calculation method, the percentage of maximum range, plus the number in brackets

                  BY62 DC 0-500V 4 Bit Voltage Current Capacity Power Temp Meter OLED Multifunction DC Electric Parameter Tester

                  BY62 DC 0-500V 4 Bit Voltage Current Capacity Power Temp Meter OLED Multifunction DC Electric Parameter Tester

                  Voltage: Voltage display
                   
                  Current: Current display
                   
                  Power: Power display
                   
                  Capacity: Capacity shows that the result of the last measurement is displayed first every time the power is connected. When this time exceeds 1mAH, it begins to be recalculated.

                  Temp: PCB temperature measurement, about two degrees higher than room temperature

                  Cumulative capacity: The result of the accumulative amount of electricity  for all measurements, If it is not cleared, it will always be accumulated.

                  Cumulative watt hour: The results of the accumulative energy of all measurements.If it is not cleared, it will always be accumulated.
                  Time:Load time

                  Alarm switch : This function is only for professional use.Used to make an instrument output a voltage signal and to control other devices.  
                  When the set is , If the voltage or current alarm condition realized, the output is 3.3V.  Otherwise output 0V
                  When the set is, the output voltage is always 0V

                  Limitch switching: This function is only for professional use.
                  When set to ,Turn the operation channel into a voltage.
                  When set to ,Turn the operation channel into a current

                  High:This function is only for professional use.
                               Limitch switching=C.VO   The value shown here is the upper limit of the voltage.
                               Limitch switching=C.CU   The value shown here is the upper limit of the current.

                  Down:This function is only for professional use.
                               Limitch switching=C.VO   The value shown here is the Lower limit of the voltage.
                               Limitch switching=C.CU   The value shown here is the Lower limit of the current

                  Very important hint: the default is 0 when the factory is out. To set up [Down], it is necessary to set up [High]. only when [Down] is less than [High], and the data will be saved successfully.

                  Key use method:
                   
                  The instrument is designed with single key and can realize various operations.
                          A: In the normal interface, the length is 3 seconds into the adjustment state. The selected adjustment items will flicker. In this state, click the button to switch back and forth in the adjustment items. When selected: real time electricity, accumulating electricity, accumulating power, double click the button to realize the zero operation. When the alarm switch is selected, the channel switches, double click switch when the channel switches. When selected: upper and lower values, double click to enter data adjustment. In adjustment state, press 3 seconds to exit.
                          B: under normal interface, double click the button (2 times in short time), enter the calibration interface. It can calibrate the voltage, current, and zero point. The adjustment range is +/-50%. When the parameters flicker, double click, enter the position adjustment (underline below the corresponding number), click the cycle to change the number, double click, change the adjustment position, and press the exit boundary. 
                  BY62 DC 0-500V 4 Bit Voltage Current Capacity Power Temp Meter OLED Multifunction DC Electric Parameter Tester

                  Supplement: this interface can also set alarm output mode. This function is very practical.
                   
                       OUT:TUNR [alarm level changes with alarm status changes]
                       OUT:HOLD [alarm level lock, when the alarm occurs, output high level, even if the alarm conditions disappear, the output level remains, until a key to restore the low level]

                  Wiring method:
                   
                  There are two sets of lines
                   
                  Three of the finer  A: groups,
                  Two thick B: group,
                   
                  Group A:
                  black wire: power supply negative pole
                  Red wire: power supply positive. Warning: the maximum can only be connected to 28V, more than damage
                  Yellow wire: connected to the positive electrode needed to measure voltage
                   
                  Group B:
                  black wire: the negative electrode of the tested power supply
                  Red wire: the negative electrode of the load to be measured. Warning: not connected to the power supply positive pole, otherwise burned

                  BY62 DC 0-500V 4 Bit Voltage Current Capacity Power Temp Meter OLED Multifunction DC Electric Parameter Tester

                  BY62 DC 0-500V 4 Bit Voltage Current Capacity Power Temp Meter OLED Multifunction DC Electric Parameter Tester

                  ►Link for BY62 monitoring software
                  BY62 DC 0-500V 4 Bit Voltage Current Capacity Power Temp Meter OLED Multifunction DC Electric Parameter Tester

                  ////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////////
                   
                  Ordinary users only need to plug a USB-TTL line into the computer, and the corresponding DNG, TX, RX table head connected, open our software, you can automatically connect, without any settings.
                   
                   
                   This protocol is for professional programmers only, for example, to achieve multi-online, other equipment interoperability. Ordinary users do not need to read.
                   
                  First.
                         device data output mode.
                  Baud rate: 19200 check digit: NONE data bits: 8 stop bits: 1
                  Each output will output a set of device information consisting of 54 bytes.
                   
                     Example: FA FC 1F 04 00 01 00 70 00 01 00 01 03 79 00 01 00 00 00 14 00 01 00 00 01 23 00 
                              00 00 25 00 02 00 00 00 A8 00 02 00 00 00 01 00 00 00 00 FF 00 00 00 00 13 01 3F 
                     Position: 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 
                              28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54
                  01 02: fixed to FA FC, data group start sign.
                  03 04: voltage data (ignoring decimal point) =03*256+04;
                  05 06: voltage decimal point. For example, 03*256+04=3000,05*256+06=3, the actual voltage is 300.0V
                  07 08: current data (ignore decimal point)
                  09 10: current decimal point position
                  11 12: current unit.11*256+12=1, when the current unit is A, when equal to 0, the unit is mA.
                  13 14: power data (ignore decimal point)
                  15 16: power decimal point position.
                  17 18: power unit. Equal to 1 indicates that the unit is KW, equal to 0, indicating that the unit is W.
                  19 20: real time capacity data (ignoring decimal point)
                  21 22: real-time capacity decimal position
                  23 24: Real-time capacity content. When equal to 1, the content is the current upper capacitance value. When equal to 0, the content is the last power-down capacity value.
                  25 26: temperature. Variable is int type. It can represent negative temperature.
                  27 28 29 30: cumulative capacity value, variable Unsigned long type.
                  31 32: cumulative capacity decimal position
                  33 34 35 36: accumulates tile time value, the variable is Unsigned long type.
                  37 38: accumulating tile decimal point position
                  39 40: running time. The unit is minute.
                  41 42: carried state. Equal to 1 indicates current value is not 0. equal to 0, indicating current value is 0.
                  43: alarm switch. Alarm function is opened when the alarm is equal to 1. When the alarm function is equal to 0, the alarm function is turned off.
                  44: upper and lower bound parameters. When equal to 1, the upper and lower bound values are displayed as voltage values. When equal to 0, the upper and lower values are displayed as current values.
                  45 the upper limit of 46: shows.
                  47 48: lower value display.
                  49 50: Device Adjustment Item Number. 0 – Device Processing Normal Standby State. 1 – Select Real Time Capacity 2 – Select Total Capacity 3 – Select Total Watt Time 4 – Select Alarm Setting 5 – Select Voltage Current (Upper and Lower Limits) Switch
                  6 – Check the upper limit 7 – Check the upper limit 8 – Check the upper limit 10 – Check the upper limit 10 – Check the upper limit 10 – Check the lower limit 15 – Check the lower limit
                  18- select lower limit ten bits 22- select lower limit 100 bits.
                  51: retained not used
                  52: check bit. All data correlation from 1 to 51. Rounding off carry. Can be used to detect data transmission error.
                  53: Device Data Output Mode. 0 – Indicates Device Stop Output Data. 1 – Indicates Device in Single Output Mode 2 – Indicates Device Processing Continuous Output Mode
                  54: device address.0-63 has 64 addresses. The factory acquiescence can be used for identification when it is 00 parallel machines.
                  Explain:
                  Instrument output data will output measurement data, equipment adjustment status, equipment information. According to the need to filter selected useful information from their own.

                  Two. 
                  How to issue instructions to equipment
                  All instructions start with 7E5F.
                  1. the action instructions for sending keys to the device:
                  Practical example: 7E 5F C5 02
                  Serial number:     01 02 03 04
                  01 02: identifies the head 03: device address +0xC0 04: action type 2- click 3- double click 4- long Click
                  2. issuing instructions for modifying addresses to the equipment:
                  Practical example: 7E 5F C5 A2
                  Serial number:     01 02 03 04
                  01 02: identifies the head 03: device address +0xC0 04: the new device address +0x80. takes effect immediately.
                  3. issuing instructions to modify the output mode to the device:
                  Practical example: 7E 5F C5 40
                  Serial number:     01 02 03 04
                  01 02:Identification Header 03:Device Address+0xC0 04:Instruction Code 40-Device Stop Output 41-Single Output 42-Continuous Output
                  4. issue mandatory instructions to the device:
                  Practical example: 7E 5F 8A
                  Serial number:     01 02 03
                  01 02:Identity Header 03:Instruction Code 8A-Unconditionally Stop Output 8B-Unconditionally Single Output A Group of Data This command ignores the device address and can be used to view the device address when forgetting that the device address is out of control.
                  Attachment: the data are all 16 hexadecimal, just for the convenience of explanation, there is no space in actual data.

                  Package Includes:

                  1 x DC Parameter Meter

                  Details Pictures:

                  Leave a Comment