                  Product Function:

                  Product adopts industrial-grade chip, high-precision SHT20 temperature and humidity sensor. Product features are two main types of classification: the functions of temperature and humidity;

                  Function of temperature are as follows:
                  The automatic identification of work mode:
                  The system automatically according to the start/stop temperature, identify work mode;
                  Start temperature > stop temperature, cooling mode'C'.
                  Start temperature < stop temperature, heating mode 'H'.

                  Cooling mode:
                  When the temperature≥Start temperature,relay conduction,red led on, refrigeration equipment begin to work;
                  When the temperature≤Stop temperature,relay disconnect, red led off, refrigeration equipment stop to work;
                  Heating mode:
                  When the temperature≤Start temperature,relay conduction, red led on, heating equipment begin to work;
                  When the temperature≥Stop temperature,relay disconnect, red led off, heating equipment stop to work;

                  Temperature correction function OFE (-10.0 ~ 10℃):

                  The system is working for a long time and may be biased, through this function correction, the actual temperature = measuring temperature + calibration value;

                   
                  How to set the start/stop temperature:

                  1. In the running interface, Long Press ' TM+ ' key more than 3 seconds, into the start temperature settings interface, can be modified by TM+ TM-key, to be modified, waiting for 6s automatic exit and save;
                  2. In the running interface, Long Press ' TM-' key more than 3 seconds, into the stop temperature settings interface,can be modified by TM+ TM-key, to be modified after the parameters, waiting for 6s automatic exit and save;

                  The humidity function is as follows:

                  The automatic identification of work mode:
                  The system automatically according to the start/stop humidity, identify work mode;
                  Start humidity> stop humidity, dehumidificationmode'D'.
                  Start humidity< stop humidity, humidificationmode 'E'.

                  Dehumidificationmode:

                  When the humidity≥Start humidity,relay conduction, green led on, dehumidification equipment begin to work;
                  When the humidity≤Stophumidity,relay disconnect, green led off, dehumidificationequipment stop to work;

                  Humidificationmode:

                  When the humidity≤Start humidity,relay conduction, green led on, humidificationequipment begin to work;
                  When the humidity≥Stophumidity,relay disconnect, green led off, humidificationequipment stop to work;

                  Humidificationcorrection function RH (-10.0 ~ 10%):
                  The system is working for a long time and may be biased, through this function correction, the actual humidity= measuring humidity+ calibration value;

                  How to set the start/stop humidity:
                  1. In the running interface, Long Press ' RH+ ' key more than 3 seconds, into the start humiditysettings interface, can be modified by RH+ RH- key, to be modified, waiting for 6s automatic exit and save;
                  2. In the running interface, Long Press ' RH-' key more than 3 seconds, into the stop humiditysettings interface, can be modified by RH+ RH- key, to be modified after the parameters, waiting for 6s automatic exit and save;

                  Running Interface Description:  

                  Working mode shows that the current mode ("H/C", "E/d") will be synchronized at the front of temperature/humidity, when the setting of temperature/humidity and stop temperature/humidity are completed.   
                  Any relay conduction, the upper-left corner of the interface display "out", if the temperature relay conduction, the flashing display temperature working mode "H/C" to show reminders; if the humidity relay conduction, then flashing display humidity working mode "E/d", as a reminder;

                  Other features:

                  Parameter remote read/set:    

                  Through the UART, set the starting temperature/humidity, stop temperature/humidity, temperature/humidity correction parameters;
                  temperature/Humidity Real-time reporting:
                  If the temperature/humidity reporting function is turned on, the product will detect the temperature/humidity and relay status by the 1s interval, and pass the UART to the terminal to facilitate data collection;
                  Relay enabling (by default):
                  If the relay is disable, the relay remains disconnected;

                  How to modify the temperature/humidity correction value:
                  1. In the operating interface, double-click the ' TM+ ' key to enter the correction of the set interface, the downward display correction of the type, the upward display of specific values; (OFE: Temperature correction value RH: Humidity correction value)
                  2.At this time by a short press ' TM-' key, switch to modify the parameters, through the RH+ RH-key, modify the specific value of the support long press short;
                  3.When the parameters have been modified, double-click the ' TM+ ' key, exit the correction positive setting interface, and save the data;
                  How to enable/disable relay:

                  In the running interface, Short press ' TM-' key,enable/disablethe temperature relay(ON: enableOFF:disable), back to the running interface, if the temperature relay is disable, the temperature symbol ' ℃ ' flashes to remind.

                  In the running interface, Short press ' RH-' key, enable/disable the humidity relay (ON: enable OFF: disable), back to the running interface, if the humidity relay is disable, the humidity symbol '% ' flashes, as a reminder.

                  Serial control(TTL level)
                  BaudRate:9600bps Data bits :8
                  stop bits :1
                  crc :none
                  Flow control :none

                  CMD

                  Description

                  start

                  start data upload

                  stop

                  stop data upload

                  read

                  Read the param setting

                  T:ON

                  Temperature relay enable

                  T:OFF

                  Temperature relay disable

                  H:ON

                  Humidityrelay enable

                  H:OFF

                  Humidity relay disable

                  TS:XX.X

                  Set start Temperature

                  (-20.0~60.0)

                  TP:XX.X

                  Set stopTemperature

                  (-20.0~60.0)

                  HS:XX.X

                  Set start Humidity

                  (00.0~100.0)

                  HP:XX.X

                  Set stopHumidity

                  (00.0~100.0)

                  TC:XX.X

                  Set TemperatureCalibration

                  (-10.0~10.0)

                  HC:XX.X

                  Set HumidityCalibration

                  (-10.0~10.0)

                  Temperature and humidity Data upload format Description:
                  Temperature format: Operating mode (H/C), temperature value, temperature relay status;
                  Humidity Format: Operating mode (E/D), humidity value, humidity relay status;
                  H,20.5℃,CL:Heating operating mode, the current temperature of 20.5 degrees, temperature relay disconnection state;
                  D,50.4%,OP:Dehumidification working mode, current humidity 50.4%, humidity relay connection;

                  Package included:

                  1 x XY-WTH1 DC 6-30V Digital Display Constant Temperature Humidity Incubator Controller